Static Headspace analysis is a time-tested and robust technique for the analysis of volatile compounds in almost any matrix. The popularity of the technique is due to Headspace analysis providing a clean, reliable result.
Overview
Teledyne Tekmar draws on our experience as a leader in low-level VOC analysis with the introduction of a next generation Headspace instrument, the HT3™ Static and Dynamic Headspace System.
Dramatic improvements in sensitivity are achieved with the new Dynamic Headspace option, while maintaining the ruggedness and reliability of a traditional Static Headspace instrument.
Applications and Industries
VOC sampling and analysis are used in a wide range of applications in the following industries:
- Pharmaceutical
- Residual Solvents
- Impurities from drug substances
- Impurities from container closure systems
- Flavor, Fragrance, and Packaging
- Petrochemical
- Blood Alcohol and Forensic Toxicology
- Polymers
- Environmental
Methods
- USP <467> (See applications above.)
- EPA Method 5021
- RSK-175
Key Features
- Standard integrated 60-position autosampler with 10-position platen heater provides true walk away automation
- Increased sensitivity from 50 to 100 times with the Dynamic Headspace option (compound dependent)
- Removable sample path for trouble-free maintenance
- High temperature capability to 300 °C expands range of applications
- Inert sample pathway including transfer line, sample needle and loop provide superior analytical results by eliminating adsorption and reducing carryover
- Automated Leak Check and Benchmark for quick troubleshooting
- Automated method development using Method Optimization Mode (M.O.M.)
- 21 CFR Compliance
- Built-in Mass Flow Controller ensures consistent flow and pressure for all samples regardless of external conditions
Application Notes
-
Meeting the Korean Method ES 04605.3 for Formaldehyde (폼알데하이드) with Static Headspace GC/MS
-
Determination of Hexanal in Foods Utilizing Dynamic Headspace GC/MS
-
Meeting the Korean Method EX 04607.1 for Naphthalene with Static and Dynamic Headspace GC/MS
-
Meeting the Korean Method ES 04601.2 for 1,4-Dioxane with Static and Dynamic Headspace GC/MS
-
Meeting the Korean Method ES 04602.1b for Vinyl Chloride, Acrylonitrile, and Bromoform with Static and Dynamic Headspace GC/MS
-
Meeting the Korean Method 04603.2b for 12 VOC with Static and Dynamic Headspace GC/MS
-
Alcoholic Beverage Fusel Alcohol Testing with Static Headspace
-
Achieving Low-Level Detection of Benzene in Beverages with an Automated Headspace Vial Sampler
-
Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers
-
Blood Alcohol Determination with The Teledyne Tekmar HT3 and Young Lin YL6500 Gas Chromatograph
-
Residual Solvents Testing ASTM F1884-04 with the Versa and HT3 Automated Headspace Sampler
-
Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water
-
Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water
-
Comparing US EPA and FDA Methods for 1,4-Dioxane in Consumer Products
-
Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175
-
Comparison of Static and Dynamic Headspace for Volatile Organic Compounds in Orange Juice
-
Comparison of BTEXS in Olive Oils by Static and Dynamic HT3 Headspace
-
Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis
-
Bath Salt Characterization using the Tekmar HT3 Headspace Analyzer GC/MS
-
Using the Teledyne Tekmar HT3 Headspace Analyzer to Meet the Requirements of the Korean Standard Method for Water Pollution, ES04602.1 for Bromoform, Vinyl Chloride and Acrylonitrile
-
Using the Teledyne Tekmar HT3 Headspace Analyzer to Meet the Requirements of the Korean Standard Method for Drinking Water, ES05602.3 for 1,4-Dioxane
-
Evaluating Food Products for Furan and Other Volatile Organic Compounds
-
Evaluating Consumer Products for Low Level Contaminants with High Temperature Dynamic Headspace
-
A Survey of Residual Solvents in Various Inks used in Consumer Product Packaging
-
USP <467> Headspace Residual Solvent Assay
-
High Temperature Headspace Assay of Polymers
-
Headspace Assay of Polymers used in the Automotive Industry
-
Headspace Assay of Household Interior Paint
-
Determination of Furan in Coffee by Static and Dynamic Headspace GC-MS
-
Gasoline Range Organics (GRO) by Headspace/GC/FID
-
Detection Limits of EPA Method 8260 with Static and Dynamic Headspace GC/MS Analysis
-
Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer
-
Determining Volatile Organic Compounds from Difficult Soil Matrices Utilizing both Headspace and Purge and Trap Techniques
-
Headspace Analysis of Volatile Organic Compounds (VOCs) in Contact Packaging Materials Using the HT3 Automated Headspace Analyzer
-
A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 Automatic Headspace Analyzer
-
Detection Limits of EPA Method 8260 with Static and Dynamic Headspace GC-MS Analysis
Downloads
Teledyne Tekmar Deutschland
Teledyne Tekmar is represented in Germany by ANTEC GmbH
Headquarters
ANTEC GmbH
Analysen- und Prozesstechnik
Hauptstraße 4
82404 Sindelsdorf
Telefon: +49 (0) 8856 9910
Telefax: +49 (0) 8856 9891
E-Mail: kontakt@teledynetekmar.de
Support
ANTEC GmbH
Technical Support
Telefon: +49 (0) 89 72069268
Telefax: +49 (0) 89 72625045
E-Mail: service@teledynetekmar.de